1. CloudMatrix 6655-48XS8CQ

      CloudMatrix 6655-48XS8CQ

      CloudMatrix 6685-48YS8CQ

      CloudMatrix 6685-48YS8CQ

      CloudMatrix 6600ϵÁÐ(50G&100G&200G)Êý¾ÝÖÐÐĽ»»»»ú

      ²úÆ·¸ÅÊö

      CloudMatrix 6600ϵÁÐÊÇjiuyou.comÃæÏòÊý¾ÝÖÐÐÄÍÆ³öµÄÐÂÒ»´ú¸ßÐÔÄÜ¡¢¸ßÃܶȵÄ10G¡¢50G½ÓÈë½»»»»ú£¨CloudMatrix£¬¼ò³ÆCM£©¡£CloudMatrix6600ϵÁвÉÓÃÏȽøµÄÓ²¼þ½á¹¹Éè¼Æ£¬Ìṩ¸ßÃÜ10G/50G¶Ë¿Ú½ÓÈ룬֧³Ö100G/200GÉÏÐж˿ڣ¬Ö§³Ö·á¸»µÄÊý¾ÝÖÐÐÄÌØÐԺ͸ßÐÔÄܵÄM-LAG£¬·çµÀ·½Ïò¿ÉÒÔÁé»îÑ¡Ôñ¡£CloudMatrix 6600ϵÁпÉÒÔÓëjiuyou.comÊý¾ÝÖÐÐĺËÐĽ»»»»úCloudMatrix 16600(-X)ÅäºÏ¹¹½¨µ¯ÐÔ¡¢ÐéÄâºÍ¸ßÆ·ÖʵÄÔÆÊ±´úÊý¾ÝÖÐÐÄ100G/200GÈ«Áª½ÓÍøÂ磬Âú×ãÔÆÊ±´úÊý¾ÝÖÐÐĶÔÍøÂçµÄÐèÇó¡£

      CloudMatrix 6600ϵÁн»»»»ú¶¨Î»ÓÚÊý¾ÝÖÐÐĵĸßÃÜ10G/50G½ÓÈ룬°ïÖúÆóÒµºÍÔËÓªÉ̹¹½¨ÃæÏòÔÆ¼ÆËãʱ´úµÄÊý¾ÝÖÐÐÄÍøÂçÆ½Ì¨£¬Ò²¿ÉÒÔÓÃÓÚÔ°ÇøÍøµÄºËÐÄ»ò»ã¾Û¡£

      CloudMatrix 6600ϵÁн»»»»ú°üÀ¨CloudMatrix 6655-48XS8CQºÍCloudMatrix 6685-48YS8CQÁ½¿îÉ豸ÐÎ̬£¬¿ÉÒÔͨ¹ýÅäÖò»Í¬·çÏòµÄµçÔ´ºÍ·çÉÈÀ´ÊµÏÖ·çÏòǰ½øºó³ö»òºó½øÇ°³öÁ½ÖÖģʽ¡£

      CloudMatrix 6600ϵÁн»»»»úʹÓõÄÊǹú²úµÄCPUºÍ½»»»Ð¾Æ¬£¬·ûºÏÏÖ½×¶ÎÐÅ´´µÄÐèÇó£¬É豸¾­¹ý¶àÄêµÄʹÓÃʵ¼ù£¬³ÉÊì¶È½Ï¸ß¡£

      CloudMatrix 6655-48XS8CQ ½»»»»úÌṩ48¸ö10GE SFP+½Ó¿Ú£¬8¸ö100GE QSFP28½Ó¿Ú,»ò8¸ö40GE QSFP+½Ó¿Ú¡£

      CloudMatrix 6685-48YS8CQ ½»»»»úĬÈÏÌṩ48¸ö25G SFP28½Ó¿Ú£¬8¸ö100GE QSFP28½Ó¿Ú£¬¿Éͨ¹ýÉý¼¶Ö§³Ö48¸ö50G SFP56½Ó¿Ú£¬8¸ö200GE QSFP56½Ó¿Ú¡£

      ²úÆ·ÌØµã

      ¸ßÃÜ¶È 10G/50G½ÓÈ룬ÈÝÁ¿³¬Èº

      l?? ×î´óÌṩ48¸ö10G/50G½Ó¿Ú£¬Âú×ã10GE·þÎñÆ÷¸ßÃܽÓÈëÐèÇ󣬯½»¬Ñݽø£»

      l?? ×î´óÖ§³Ö8¸ö100G/200G¸ßÐÔÄÜQSFP28/56½Ó¿Ú£¬QSFP28/56½Ó¿ÚÔÊÐí×÷Ϊ1¸ö40GE QSFP+½Ó¿Ú£¬ÌṩÁé»îµÄ×éÍøÄÜÁ¦£»100G/200GÉÏÐÐÓëCloudMatrix 16600(-X) ϵÁй²Í¬¹¹½¨ÎÞ×èÈûµÄÍøÂçÆ½Ì¨¡£

      ¿çÉ豸Á´Â·¾ÛºÏ£¬¸ßЧ¿É¿¿

      ¸ÃϵÁн»»»»úÖ§³Ö¿çÉ豸Á´Â·¾ÛºÏ M-LAG£¨Multichassis Link Aggregation Group£©£¬Äܹ»ÊµÏÖ¶ą̀É豸¼äµÄÁ´Â·¾ÛºÏ£¬´Ó¶ø°ÑÁ´Â·¿É¿¿ÐÔ´Óµ¥°å¼¶Ìáµ½É豸¼¶£»

      l?? ¶à»îϵͳ£¬Ò»·½ÃæË«¹éϵͳʵÏÖÁ÷Á¿¸ºÔØ·Öµ££¬ÁíÒ»·½ÃæÏµÍ³¶à»î¡¢Èȱ¸·Ý±£»¤£¬ÏµÍ³¸ü¿É¿¿£»

      l?? M-LAG µÄ¸÷½ÚµãÉ豸¿É¶ÀÁ¢Éý¼¶£¬Éý¼¶¹ý³ÌÖÐÆäËü½Úµã³Ð½ÓÒµÎñת·¢£¬ÊµÏÖÒµÎñÁãÖжϣ»

      l?? ×éÍøÁé»î£¬ÆÕͨÒÔÌ«ÍøÂç¡¢VXLAN ÒÔ¼° IP ÍøÂçµÄË«¹é½ÓÈë¾ù¿É²ÉÓà M-LAG ½ÓÈ뷽ʽ¡£

      ÐéÄ⻯Ӳ¼þÍø¹Ø£¬¿ìËÙ²¿Êð

      l?? ¸ÃϵÁн»»»»ú¿ÉÒÔÓëÒµ½çÖ÷Á÷µÄÐéÄ⻯ƽ̨ÅäºÏ£¬×÷Ϊ Overlay ÐéÄâ»¯ÍøÂ磨VXLAN£©µÄ¸ßÐÔÄÜÓ²¼þÍø¹Ø£¬Ö§³Å¸ß´ï 16M ¶à×â»§µÄÊý¾ÝÖÐÐÄÔËÓª£»

      l?? ¸ÃϵÁн»»»»ú×÷ Overlay ÍøÂçµÄÓ²¼þÍø¹ØÊ±£¬¿ÉÒÔͨ¹ý Open API ÓëÔÆÆ½Ì¨¿ª·Å¶Ô½Ó£¬ÊµÏÖÈí¼þÍøÂçºÍÓ²¼þÍøÂçµÄͳһ¹ÜÀí£»

      l?? Ó²¼þÐéÄâ»¯Íø¹Ø·½°¸ÎÞÐè¸Ä¶¯¿Í»§ÏÖÍø£¬ÊµÏÖÒµÎñµÄ¿ìËÙ²¿Êð£¬Í¬Ê±±£»¤ÍøÂçͶ×Ê£»

      l?? Ö§³Ö BGP-EVPN ×÷Ϊ VXLAN µÄ¿ØÖÆÆ½Ã棬¼ò»¯ DCÄÚ¡¢DC¼äµÄ VXLAN µÄÅäÖá£

      ¿ª·Å¿É±à³ÌÍøÂ磬Áé»î¶¨ÖÆ

      l?? ¸ÃϵÁн»»»»úÖ§³Ö NetConf ЭÒ飬¿ÉÓëiMaster NCM-Fabric ¶Ô½Ó£»

      l?? ¸ÃϵÁн»»»»úÖ§³Ö×Ô¶¯»¯¹ÜÀíÔËά¹¤¾ß£¬ÊµÏÖÎïÀí¡¢ÐéÄâÍøÂçµÄͳһ·¢·Å£»

      l?? ¸ÃϵÁн»»»»ú¿É±»Òµ½çÖ÷Á÷ÔÆÆ½Ì¨£¨º¬ÉÌÒµÔÆÆ½Ì¨ºÍ¿ªÔ´ÔÆÆ½Ì¨£©ºÍµÚÈý·½ Controller Éî¶È¼¯³É£¬Ö§³ÖÒµÎñ¶ÔÍøÂçµÄÁé»î¶¨ÖƺÍ×Ô¶¯»¯¹ÜÀí¡£

      É豸ÁãÅäÖò¿Êð£¬×Ô¶¯ÔËά

      l?? ¸ÃϵÁн»»»»úÖ§³Ö ZTP£¨Zero Touch Provisioning£©Ð­Ò飬¿ÉÒÔÎļþ·þÎñÆ÷»ñÈ¡°æ±¾Îļþ²¢×Ô¶¯¼ÓÔØ£¬ÊµÏÖÉ豸µÄÃâÏÖ³¡ÅäÖúͲ¿Ê𣬴Ӷø½µµÍÈËÁ¦³É±¾£¬ÌáÉý²¿ÊðЧÂÊ£»

      l?? ZTP ¹¦ÄÜÖ§³ÖÄÚǶ½Å±¾ÓïÑÔ£¬²¢Í¨¹ý Open API ¿ª·Å¸øÓû§£¬Êý¾ÝÖÐÐÄÓû§¿ÉʹÓÃÆäÊìϤµÄ½Å±¾ÓïÑÔ£¨Python µÈ£©ÊµÏÖ¶ÔÍøÂçÉ豸µÄͳһÅäÖã»

      l?? ZTP ʵÏÖÐÂÉ豸ÅäÖÃʱ¼äÓëÉ豸ÊýÁ¿¡¢µØÓò·Ö²¼½âñËõ¶ÌÒµÎñÉÏÏßʱ¼ä£¬Ìá¸ßÁËÒµÎñÉÏÏßЧÂÊ¡£

      ÖÇÄÜÎÞËðÍøÂ磬Âú×ã RoCEv2 Ó¦ÓøßÐÔÄÜÐèÇó

      l?? ¸ÃϵÁн»»»»úÖ§³ÖÖÇÄÜÎÞËðËã·¨£¬½â¾ö´«Í³ÒÔÌ«ÍøÂçÓµÈû¶ª°üµÄÎÊÌ⣬ΪRoCEv2 Á÷Á¿Ìṩ¡°ÎÞ¶ª°ü¡¢µÍʱÑÓ¡¢¸ßÍÌÍ¡±µÄÍøÂç»·¾³£¬Âú×ãRoCEv2 Ó¦ÓõĸßÐÔÄÜÐèÇó¡£

      l?? ¸ÃϵÁн»»»»úÖ§³ÖPFCËÀËøÔ¤·À£¬Í¨¹ýʶ±ðÒ×Ôì³É PFC ËÀËøµÄÒµÎñÁ÷£¬Ð޸ĶÓÁÐÓÅÏȼ¶£¬´Ó¶øÔ¤·À PFCËÀËøµÄ·¢Éú¡£

      l?? ¸ÃϵÁн»»»»úÖ§³Ö AI ECN£¨Artificial Intelligence Explicit Congestion Notification£©£¬¸ù¾ÝÏÖÍøÁ÷Á¿Ä£ÐÍÖÇÄܵ÷ÕûÎÞËð¶ÓÁÐµÄ ECN ÃÅÏÞ£¬¿ÉÒÔ±£ÕÏÁ㶪°üϵĵÍʱÑӺ͸ßÍÌÍ£¬ÈÃÎÞËðÒµÎñ´ïµ½×îÓÅÐÔÄÜ¡£

      l?? ¸ÃϵÁн»»»»úÖ§³ÖECN Overlay ¹¦ÄÜ£¬½«ECN ¹¦ÄÜÓ¦Óõ½ VXLAN ÍøÂçÖУ¬Ê¹ Overlay ÍøÂçÖеÄÓµÈû״̬¿ÉÒÔ¼°Ê±±»Á÷Á¿½ÓÊն˸ÐÖª£¬ÈÃÁ÷Á¿½ÓÊÕ¶ËÖª»áÁ÷Á¿·¢ËͶ˽øÐнµËÙ£¬»º½âÍøÂçÓµÈû¡£

      ÑϸñµÄǰºó·çµÀ£¬¸ßЧ½ÚÄÜ

      Áé»îµÄǰºó/ºóǰ·çµÀÉè¼Æ£º

      l?? ²ÉÓÃÑϸñµÄǰºó·çµÀÉè¼Æ£¬Ö§³ÖÀäÈÈ·çµÀÍêÈ«¸ôÀ룬ÌáÉýÉ¢ÈȵÄЧÂÊ£¬Âú×ãÊý¾ÝÖÐÐÄ»ú·¿Éè¼ÆÒªÇó£»

      l?? ͨ¹ýÑ¡Åä·çÉȺ͵çÔ´Ä£¿é£¬Áé»îÖ§³ÖǰºóºÍºóǰ·çµÀ£»

      l?? Ö§³ÖµçÔ´ºÍ·çÉÈÈßÓàÅäÖ㬱£ÕÏÒµÎñÎÞ¼ä¶ÏÔËÐС£´´ÐµĽÚÄܼ¼Êõ£º

      l?? ʹÓýÚÄÜоƬ£¬ÖÇÄܵķçÉȵ÷ËÙ·½°¸£¬Ö§³Öʵʱ¹¦ºÄ¼ì²â£¬Îª¿Í»§½µµÍÔËά³É±¾£¬´òÔìÂÌÉ«Êý¾ÝÖÐÐÄ¡£

      ָʾµÆÍêÃÀ³ÊÏÖ£¬ÔËά¼òµ¥

      ÇåÎúµÄָʾµÆ£º

      l?? Ö§³Ö¶Ë¿Ú״̬¡¢¶Ë¿ÚËÙÂʵÈÐÅÏ¢µÄÍêÕû³ÊÏÖ£¬´´Ð嵀 100GE ¶Ë¿ÚָʾµÆ£¬¿ÉÒÔÇåÎúÏÔʾËùÓÐ×Ó¶Ë¿Ú״̬£»

      l?? Ç°Ãæ°åºÍºóÃæ°åͬ²½ÏÔʾϵͳ״̬£¬±ãÓÚ´ÓÈÎÒâ·½Ïòά»¤£»

      l?? Ö§³ÖÔ¶³Ì¶¨Î»¹¦ÄÜ£¬ÔÚÍø¹Ü/¿ØÖÆÌ¨ÉÏ¿ÉÒÔµãÁÁÐèҪά»¤É豸µÄÔ¶³Ì¶¨Î»Ö¸Ê¾µÆ£¬±ãÓÚÔÚÓµ¼·µÄÉ豸¼ä׼ȷ¶¨Î»É豸¡£

      ά»¤¼òµ¥

      l?? ¹ÜÀí½Ó¿Ú/·çÉÈ/µçԴλÓÚ½»»»»úµÄÕýÃæ£¬±ãÓÚά»¤£»

      l?? Êý¾Ý½Ó¿ÚλÓÚ½»»»»úµÄºó²à£¬ºÍ·þÎñÆ÷ͬÏò£¬±ãÓÚ×ßÏß¡£


      ²úÆ·¹æ¸ñ

      ÏîÄ¿CloudMatrix 6655-48XS8CQCloudMatrix ? 6685-48XS8CQ
      ¶Ë¿Ú48¸ö10G½Ó¿Ú+ ? 8¸ö100G½Ó¿Ú48¸ö25G£¨¿ÉÉý¼¶Îª50G£©½Ó¿Ú+ ? 8¸ö100G£¨¿ÉÉý¼¶Îª200G£©½Ó¿Ú
      ½»»»ÈÝÁ¿4.8Tbps/96Tbps8Tbps/96Tbps
      °üת·¢ÂÊ2,000Mpps2,400Mpps
      ·çµÀÀàÐͱê׼ǰºó»òºóǰ·çµÀ
      É豸ÐéÄ⻯֧³Ö M-LAG
      ÍøÂçÐéÄ⻯֧ ³Ö VXLAN routing ºÍ VXLAN bridging
      Ö§ ³Ö BGP-EVPN
      ÍøÂçÈÚºÏÖ§³Ö RDMA ºÍ RoCE£¨RoCE v1 ºÍ RoCE v2£©
      Ö§³Ö PFC ºÍ AI ECN
      ¿É±à³ÌÌØÐÔÖ§³Ö OpenFlow ЭÒé
      Ö§³Ö ¿É±à³Ì
      Á÷Á¿·ÖÎöÖ§³Ö Netstream ¹¦ÄÜ
      VLANÖ§³Ö Access¡¢Trunk¡¢Hybrid ·½Ê½
      Ö§³Ö default VLAN
      MAC µØÖ·±íÖ§³Ö MAC µØÖ·×Ô¶¯Ñ§Ï°ºÍÀÏ»¯
      Ö§³Ö¾²Ì¬¡¢¶¯Ì¬¡¢ºÚ¶´ MAC ±íÏî
      Ö§³ÖÔ´ MAC µØÖ·¹ýÂË
      Ö§³Ö»ùÓÚ¶Ë¿ÚºÍ VLAN µÄ MAC µØÖ·Ñ§Ï°ÏÞÖÆ
      IP ·ÓÉÖ§³Ö RIP¡¢OSPF¡¢ISIS¡¢BGP µÈ IPv4 ¶¯Ì¬Â·ÓÉЭÒé
      Ö§³Ö RIPng¡¢OSPFv3¡¢ISISv6¡¢BGP4+µÈ IPv6 ¶¯Ì¬Â·ÓÉЭÒé
      IPv6VXLAN Over IPv6
      IPv6 VXLAN over IPv4
      Ö§³Ö IPv6 ND£¨Neighbor Discovery£©
      Ö§³Ö PMTU ·¢ÏÖ£¨Path MTU Discovery£©
      Ö§³Ö IPv6 µÄ TCP¡¢Ping ¡¢Tracert¡¢Socket¡¢UDP¡¢RawIP
      ×é²¥Ö§³Ö IGMP¡¢PIM-SM¡¢MSDP µÈ×鲥·ÓÉЭÒé
      Ö§³Ö IGMP Snooping
      Ö§³Ö IGMP? Proxy
      Ö§³Ö×é²¥³ÉÔ±½Ó¿Ú¿ìËÙÀ뿪
      Ö§³Ö×é²¥Á÷Á¿ÒÖÖÆ
      Ö§³Ö×é²¥NAT?
      ¿É¿¿ÐÔÖ§³Ö LACP
      Ö§³Ö STP¡¢RSTP¡¢PVST ºÍ MSTP
      Ö§³Ö BPDU ±£»¤
      Ö§³Ö SmartLink ¼°¶àʵÀý
      Ö§³ÖÓ²¼þ BFD£¨Bidirectional Forwarding Detection£©£¬×îС 3.3ms ·¢°ü¼ä¸ô
      Ö§³Ö VRRP¡¢VRRP ¸ºÔØ·Öµ£¡¢BFD for VRRP
      Ö§³Ö BFD for BGP/IS-IS/OSPF/¾²Ì¬Â·ÓÉ
      Ö§³Ö BFD for VXLAN
      Ö§³ÖÊý¾ÝÃæ¹ÊÕÏ¿ìËÙ×ÔÓúDPFR
      QoSÖ§³Ö»ùÓÚ Layer2 ЭÒéÍ·¡¢Layer3 ЭÒé¡¢Layer4 ЭÒéÓÅÏȼ¶µÈµÄ×éºÏÁ÷·ÖÀà
      Ö§³Ö ACL¡¢CAR¡¢Remark¡¢Schedule µÈ¶¯×÷
      Ö§³Ö PQ¡¢DRR¡¢PQ+DRR µÈ¶ÓÁе÷¶È·½Ê½
      Ö§³Ö WRED¡¢Î²¶ªÆúµÈÓµÈû±ÜÃâ»úÖÆ
      Ö§³ÖÁ÷Á¿ÕûÐΣ¬Ö§³Ö1588v2£¨PTP£©
      ÖÇÄÜÔËά֧³ÖÈ«ÍøÂ·¾¶Ì½²â
      Ö§³Ö Telemetry
      Ö§³Ö ERSPAN ÔöÇ¿
      Ö§³ÖIFIT
      Ö§³Ö PacketEvent£º¶ª°ü¿ÉÊÓ£¬³¬³¤Ê±ÑÓ¿ÉÊÓ
      Ö§³Ö VXLAN OAM: VXLAN ping, VXLAN tracert
      Ö§³ÖNetstreamÂú×ã10GE 1:1²ÉÑù
      ÖÇÄÜÎÞËð¹¦ÄÜPFCËÀËøÔ¤·À
      AI ECN
      ECN Overlay
      NSLBÔöÇ¿
      ÅäÖÃÓëά»¤Ö§³Ö Console¡¢Telnet¡¢SSH µÈÖÕ¶Ë·þÎñ
      Ö§³Ö SNMPv1/v2/v3 µÈÍøÂç¹ÜÀíЭÒé
      Ö§³Öͨ¹ý FTP¡¢TFTP ·½Ê½ÉÏÔØ¡¢ÏÂÔØÎļþ
      Ö§³Ö BootROM Éý¼¶ºÍÔ¶³ÌÔÚÏßÉý¼¶
      Ö§³ÖÈȲ¹¶¡
      Ö§³ÖÓû§²Ù×÷ÈÕÖ¾
      Ö§³ÖÅäÖûعö
      Ö§³Ö ZTP
      °²È«ºÍ¹ÜÀíMACsec
      ÃüÁîÐзּ¶±£»¤¡¢Î´ÊÚȨÓû§ÎÞ·¨ÇÖÈë
      Ö§³Ö·ÀÖ¹ DOS¡¢ARP ¹¥»÷¹¦ÄÜ¡¢ICMP ·À¹¥»÷
      Ö§³Ö¶Ë¿Ú¸ôÀë¡¢¶Ë¿Ú°²È«¡¢Sticky MAC
      Ö§³Ö IP¡¢MAC¡¢¶Ë¿Ú¡¢VLAN µÄ×éºÏ°ó¶¨
      Ö§³Ö AAA¡¢Radius¡¢TACACS µÈ¶àÖÖÈÏÖ¤·½Ê½
      Ö§³Ö RMON
      Ö§³ÖÈõ°²È«Ð­Òé/Ëã·¨²éѯÓ밲ȫÔöÇ¿
      »úÏä³ß´ç mm£¨¿í¡ÁÉî¡Á¸ß£©442¡Á420¡Á43.6
      ÂúÅäÖØÁ¿8.35kg9.2kg
      »·¾³ÒªÇó¹¤×÷ζÈ£º0¡æ¡«40¡æ£¨0m¡«1800m£© ´æ´¢Î¶È£º-40¡æ¡«+70¡æ
      Ïà¶Ôʪ¶È£º5%RH¡«95%RH£¬·ÇÄý¶
      ¹¤×÷µçѹAC£º90V¡«290V£»DC: -38.4V~-72V£»HVDC: 190V~400V
      µäÐ͹¦ºÄ147W48x25G+8x100G: ? 147W
      ? ? 48x50G+8x200G: 177W


      ¶©»õÐÅÏ¢

      ÐͺÅ

      ÃèÊö

      CM6655-48XS8CQ

      CM6655-48XS8CQ½»»»»ú(48*10GE SFP28,8*100GE QSFP28, ,3¸ö·çÉȲÛλ,2¸öµçÔ´²Ûλ,²»º¬µçÔ´·çÉÈ)

      CM6685-48YS8CQ

      CM6685-48YS8CQ½»»»»ú(48*25GE SFP56,8*100GE QSFP56, ,5¸ö·çÉȲÛλ,2¸öµçÔ´²Ûλ,²»º¬µçÔ´·çÉÈ,25G¿ÉÉý¼¶Îª50G,100G¿ÉÉý¼¶Îª200G)

      CE66-RTU-U48S8CQ

      ÏÂÐÐ 48*25G Éý¼¶µ½ 48*50G, ÉÏÐÐ 8*100G Éý¼¶µ½ 8*200G ÈÝÁ¿Éý¼¶ RTU

      FAN-031A-B

      ·ç»úºÐ(B,·ç»úºÐÃæ°å²à³ö·ç)

      FAN-031A-F

      ·ç»úºÐ(F,·ç»úºÐÃæ°å²à½ø·ç)

      PAC600S12-PF

      600W ½»Á÷µçÔ´Ä£¿é(ǰºó·çµÀ£¬µçÔ´Ãæ°å²à½ø·ç)

      PAC600S12-PB

      600W ½»Á÷µçÔ´Ä£¿é(ºóǰ·çµÀ£¬µçÔ´Ãæ°å²à³ö·ç)

      PDC1K2S12-PB

      1200WÖ±Á÷µçÔ´Ä£¿é(ǰºó·çµÀ,µçÔ´Ãæ°å²à½ø·ç)

      PDC1K2S12-CE

      1200WÖ±Á÷µçÔ´Ä£¿é(ºóǰ·çµÀ,µçÔ´Ãæ°å²à³ö·ç)

      N1-CM66LIC-CFFD

      N1-CM6600½»»»»úCloudFabric FoundationÈí¼þ°ü

      N1-CM66LIC-CFFD VxLAN

      N1-CM6600½»»»»úCloudFabric Foundation VxLANÈí¼þ°ü

      N1-CM66CFFD-SnS1Y

      N1-CM6600½»»»»úCloudFabric FoundationÈí¼þ°ü-Subscription and ? Support-Äê


      ÎĵµÖ§³Ö

      ¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿